Is your Hisense dehumidifier unable to beat the dampness? While feeling lost, you take a quick look at the display to see a flashing E9 error code.
The Hisense dehumidifier error code E9 indicates a problem with the humidity sensor, which makes it difficult for the appliance to regulate humidity .We’ll dive deep to investigate the causes behind this error response. Also, we’ll explore possible fixes that can get your Hisense dehumidifier back on track.
This guide applies to various Hisense dehumidifier models, especially those with capacities ranging between 20 and 70 pints.
Here are a few of them:
- Hisense DH-50F1W
- Hisense DH-70KP1WG
- Hisense AEB-30C1HG
- Hisense DH-50F1W
- Hisense DH-70KP1WG
- Hisense AEB-30C1HG
- Hisense AP0822CW1W
- Hisense CDH-50F3WG
- Hisense DEH50C1W
- Hisense HSDEH50X3
- Hisense CDH-70F3WG
- Hisense HSDEH30X3
- Hisense AEG-50L6W
What Does E9 Mean On A Hisense Dehumidifier?
The E9 error on your Hisense unit is a huge hassle but it is not there for your inconvenience. It serves a crucial purpose. Here’s a breakdown of its meaning and significance:
- Meaning: This error message points to a fault in the humidity sensor, affecting the dehumidifier’s ability to monitor and control humidity levels.
- Safety Feature: While disturbing, the E9 message acts as a safety feature. It prevents your dehumidifier from operating with a defective sensor. This will not only cause inaccurate humidity controls but also cause over-condensation.
- Impact on Use: A flashing E9 error code makes your dehumidifier inoperable. This forces you to deal with moisture-related issues like a damp environment, mold growth, and overall discomfort.
- Warning Signs: Right before the blinking warning, you might notice the dehumidifier running continuously despite reaching its target humidity or failing to remove moisture effectively.
- Importance of Addressing: Promptly addressing the E9 error is vital to restore functionality, prevent damage to the unit, and maintain a comfortable and safe environment.
Why Does Your Hisense Dehumidifier Show E9 Error?
The main cause behind your Hisense appliance E9 error is a faulty sensor. But this is not the only culprit. Other potential culprits are to blame for the uncomfortable moisture levels in your home. Let’s reveal all the possible causes:
1. Sensor Malfunction
The humidity sensor of your Hisense Dehumidifier has an essential role in its function. It constantly monitors the air’s moisture level and orders the dehumidifier to run to remove excess humidity.
However, this component can encounter malfunctions that make it fail to gauge and manage the humidity levels accurately. Dust buildup, first-hand component wear, or even manufacturing defects can disrupt its ability to accurately detect moisture levels, triggering the E9 code.
2. Loose Connections
Your Hisense dehumidifier relies on its control board for regulating and supervising its functions. This boar receives electrical signals from the sensor regarding the time to run. Faulty electrical connections between these two components can cause communication issues.
Loose electrical connections disrupt the flow of signals from the sensor, resulting in the E9 code and erratic dehumidifier behavior.
3. Environmental Extreme Conditions
While a rare problem, it might trigger your Hisense dehumidifier error code E9. On extremely hot or humid summer days, the sensor may get confused. This makes it struggle to adjust to such sudden spikes. Eventually, the sensor may encounter glitches and trigger the error response until conditions return to normal.
4. Control Board Problems
As the brain of your dehumidifier, the circuit or control board might encounter issues occasionally. This board contains delicate circuits, components, and wires. One or more of these elements may not function as expected.
In rare cases, the E9 error might indicate a problem with the dehumidifier’s circuit board. This could be due to a faulty component or electrical malfunction on the board. The problems of these boards are generally complex and require an experienced HVAC tech.
5. Frozen Evaporator Coil
Your Hisense dehumidifier evaporator coils are cold metal tubes. These coils attract moist air and make it condense on them.
The coils may freeze in colder conditions or when the dehumidifier absorbs too much moisture. This prevents the dehumidifier from functioning correctly and resulting in the E9 error.
6. Clogged Air Filter
A dehumidifier air filter is like a mesh screen inside your dehumidifier. Its job is to trap dust, dirt, and other tiny particles floating in the air. This keeps the internal components, especially the evaporator coils, clean.
If the air filter gets clogged with dust and debris, it can restrict airflow to the coils. With limited airflow, the coils might struggle to absorb moisture from the air as efficiently. This can confuse the humidity sensor.
How To Reset Hisense Dehumidifier E9 Error
A humidifier is like any other electrical appliance. It encounters temporary glitches, minor bugs, and malfunctions that may trigger the E9 error. A reset clears the dehumidifier’s memory and restarts its internal processes. Here’s how to do it:
- Turn off the dehumidifier and unplug it from the wall outlet.
- Leave it unplugged for at least 7 minutes to allow the appliance to rest and discharge any electricity residue.
- While the dehumidifier is unplugged, empty the water tank completely. This ensures no residual moisture triggers the sensor upon restart
- Plug the dehumidifier back into the wall outlet.
How To Fix Hisense Dehumidifier E9 Error
While fighting humidity, a Hisense dehumidifier with an E9 error can be a disappointment. The first thing that comes to mind is calling a dehumidifier expert expert. However, you can try these DIY fixes before an appliance expert. These solutions are from personal experience with different dehumidifiers.
1. How To Fix Sensor Malfunction
The sensor of your dehumidifier is an internal component. So, you may want to consult the user’s guide to determine its exact location. Keep the guide close and let’s troubleshoot this sensor:
- Use a screwdriver to remove the appliance’s back panel. This gives you an access to the sensor.
- Look for it near the air intake grill. It is a thin and rectangular electrical device with wires attached to it. It might be exposed or protected by a plastic cover.
- Use a soft brush to clean the sensor, as dirt buildup can interfere with its function.
- If the sensor appears damaged, disconnect it from the wires and install a new one.
2. How To Fix Loose Connections
To check these connections you will need to access the control panel. Remove the back cover once again for access. Now, follow these steps:
- Look for a large flat circuit board with various electrical components and wires attached.
- Trace the wires connecting the sensor with the board.
- If you find any loose connections, push them back to ensure a secure fit.
- If you are comfortable with an advanced DIY fix, use a soldering iron to solder loose wires.
- In cases, none of these fixes work, call a professional technician. Meanwhile, avoid manipulating any other components.
3. How To Fix Environmental Extreme Conditions
Fortunately, there are no fixes required for this issue. All you can do is wait for the environment to return to normal. You can try turning off the dehumidifier for a few hours and then restarting it. So, it requires some patience.
4. How To Fix Control Board Problems
DIY fixing of any control board issues is not recommended. These issues go beyond simple DIY fixes. These delicate components require specialized knowledge and tools to diagnose and repair safely.
5. How To Fix Frozen Evaporator Coil
If you suspect frozen coils, you should try to defrost the humidifier. This fix doesn’t require any tools or skills, you need to turn the unit off and allow the ice to melt naturally. However, you will need to find out the causes behind the frost formation on the coils. Investigating this matter requires a set of trained hands and eyes to detect the underlying causes. So, call a reliable Hisense dehumidifier technician.
6. How To Fix Clogged Air Filter
Addressing the air filter problems of your Hisense dehumidifier requires basic DIY skills. Here’s what to do to fix a clogged filter:
- Look for this filter behind a protective panel at your dehumidifier’s back or front part. The location varies based on the model. So, check the manual for the correct location info.
- Pull the mesh filter forward to remove it from its housing.
- Clean it with lukewarm water.
- Get a new filter if there are cracked areas on its surface.
Remember that any of these fixes require removing the dehumidifier’s power cord from the outlet. Don’t attempt these repairs when there is electricity reaching the appliance.
Conclusion
the E9 error on your Hisense dehumidifier indicates a problem with the humidity sensor, affecting its ability to control moisture levels accurately.
Possible causes include a faulty sensor, loose connections, extreme conditions, control board problems, frozen coils, or a clogged filter. Try simple DIY fixes like this sensor cleaning, loose connection checks, and air filter replacements.
But remember complex issues like control board issues and frozen evaporator coils require professional attention.
Don’t let humidity win! Take control and restore your Hisense dehumidifier’s functionality today.
Dehumidifier Vs Air Conditioner: Which Is Right for Your Home?